The fall protection requirement for employee who is constructing leading edge work.

  1. Identify the fall protection requirement from 29 CFR 1926.501(b)(1).
  2. Identify the fall protection requirement for employee who is constructing leading edge work.
  3. Identify the full requirements to protect employees from falling through holes under 29 CFR 1926.501(b)(4).
  4. What if the definition of floor hole under 29 CFR.500?
  5. Identify the requirement from 29 CFR 1926.501(b)(7)(i).
  6. Identify the full requirement for protection from falling through wall openings.
  7. What is the definition of Opening under 29 CFR 1926.500.
  8. Identify all of the protection requirements from falling objects under 29 CFR 1926.501.
  9. Identify the height requirements for a standard guardrail system to include: top rail, midrail and toeboard.
  10. What are the test load (force) requirements for the top rail, midrail and toeboards?
  11. Identify the full requirements for Covers used to protect holes in floors, roofs, and walking working surfaces.
  12. Identify the requirement of 29 CFR 1926.502(c )(3).
  13. Identify the requirement of 29 CFR 1926.502(d).
  14. What is the minimum tensile strength of dee-rings and snap hooks?
  15. What is the requirement of 29 CFR 1926.502(d)(5)?
  16. What is the requirement of 29 CFR 1926.502(d)(9)?
  17. What is the requirement of 29 CFR 1926.502(d)(12)?
  18. What is the requirement of 29 CFR 1926.502(d)(13)?
  19. What is the requirement of 29 CFR 1926.502(d)(15)?
  20. Identify the full requirement to remove fall arrest systems from service after a fall.
  21. What is the requirement of 29 CFR 1926.502(d)(20)?
  22. What is the requirement of 29 CFR 1926.502(e)(2)?
  23. What is the full capacity requirement under 29 CFR 1926.451(a)?
  24. What is the full capacity requirement under 29 CFR 1926.451(b)?
  25. What is the full requirement for open spaces on platform units?
  26. What is the full requirement under 29 CFR 1926.451(b)(2)?
  27. What is the full requirement for extending beyond support under 29 CFR 1926.451(b)(5)(i)?
  28. What is the full requirement for extending beyond support under 29 CFR 1926.451(b)(7)?
  29. What is the full requirement to prevent tipping under 29 CFR 1926.451(c)(1)?
  30. What is the full requirements for supported scaffolds under 29 CFR 451(c ) (2) all sections (6 points)?
  31. What is the full requirement for access under 29 CFR 1926.451(e)(1)?
  32. What is the full requirement for fall protection under 29 CFR 1926.451(g)(1)?